Product Features:
3621 (HTU-352A-1) of UV curable adhesive is single component, high viscosity, UV/ visible light cured acrylic adhesive modified with surface dry, good in the air, after curing the adhesive layer is formed and tough, resistant to shock and vibration resistance of the fine. It is special formula which has excellent anti moisture performance. With anaerobic curing and heating curing properties of partially cured, make light cannot reach to more completely, also can match with the accelerator curing.
Item | Unit | Typical Value | ||
Color | Component A | Yellow | ||
Component of Basic Materials | Modified acrylate | |||
Density | Component A | g/cm3 | 1.05 | |
Viscosity | Component A | mPa*s | 12000-19000 | |
Curing energy (mj/cm2) | 800 | |||
Handing Curing Time | second | 20 | ||
Initial Curing Time | hour | |||
Full Curing Time | second | 5 | ||
Tensile Strength | After Curing | Mpa | 45 | |
Shear strength | % | 12 | ||
Hardness | Shore D | 68 | ||
water absorption (24h,25℃) | (%) | 3.50 | ||
glass state temperature | (℃) | 50 | ||
Stainless steel /PP drawing strength | Kg | 5.8 | ||
Work Temperature | ℃ | -30-150 |
Typical use
In the Electronic industrial production of glass, metal and other materials for bonding, sealing, coats.
Direction for use
The glued material surface should be dry, no oil.
When applied to the adhesive curing light intensity is not lower than 40mW/cm2, was applied to the surface coating time strength of not less than 100mW/cm2.
Matters need attention
Keep it away from children. Ø
Use it in ventilated places
In case of contact with skins, wipe and then flush with clear water.
In case of contact with eyes, flush with clear water immediately and go to hospital for checking.
Package
250g/tube, 10 tubes/Carton
Storage
Store it in dry and shady places at the temperature of 10~26℃
Storage period is 12 months